6
Air Conditioner
Installation Places
1. Indoor unit
Cassette type
• There should not be any heat source or steam
near the unit.
• There should not be any obstacles to prevent the
air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, or other obstacles.
The indoor unit must keep the maintenance space.
Unit : mm
Ceiling
Ceiling Board
Ceiling Board
Above 1800
3600 or less
1000
or more
500
or more
500
or more
300 or less
Floor
15±3
10 or
more
Installation Places
The indoor unit installation
1. Cassette type
Level gauge
Ceiling
Ceiling board
Unit:mm
875
(Ceiling opening)
787
(Hanging bolt)
684
(Hanging bolt)
671
875
(Ceiling opening)
840 Unit size
840 Unit size
CAUTION :
• This air-conditioner uses a drain
pump.
Install the unit horizontally using
a level gauge.
During the installation, care should be
taken not to damage electric wires.
• Select and mark the position for fixing bolts and piping
hole.
• Decide the position for fixing bolts slightly tilted to the
drain direction after considering the direction of drain
hose.
• Drill the hole for anchor bolt on the wall.
h
Please use an annexed sheet or the
corrugated cardboard on the bottom of
packing as installation sheet.
Annexed sheet
Or
Packing corrugated
cardboard on the
bottom